DocumentCode
1395807
Title
A new method of measuring the input admittance of ultra-high-frequency triodes
Author
Takashima, K. ; Misugi, T.
Author_Institution
Kobe Kogyo Corporation, Kobe, Japan
Volume
105
Issue
10
fYear
1958
fDate
5/1/1958 12:00:00 AM
Firstpage
583
Lastpage
585
Abstract
The paper deals with a new method of measuring the input admittance of a triode at ultra-high frequencies. In contrast to the method described by S. D. Robertson1 and others2, 3, 4 the proposed method uses a combination of resonance and standing-wave methods with the advantages of simplicity of operation and the feasibility of measurement with large signal input. Measurements have been carried out with a u.h.f. triode of type 2C39A in the 2.7 Gc/s band for input powers up to 3 watts.