DocumentCode
1398126
Title
Magnetic field analysis of stator core end region of large turbogenerators
Author
Fujita, Masafumi ; Tokumasu, Tadashi ; Yoda, Hiroyuki ; Tsuda, Hideaki ; Ito, Kaoru ; Nagano, Susumu
Author_Institution
Toshiba Corp., Yokohama, Japan
Volume
36
Issue
4
fYear
2000
fDate
7/1/2000 12:00:00 AM
Firstpage
1850
Lastpage
1853
Abstract
In order to estimate the losses and temperature rise at the end of electrical machines, it is important to clarify electromagnetic behavior in the core end region. In this paper, the method of evaluating the leakage flux of the stator end region of large turbogenerators, combining three-dimensional magnetic field analysis and phasor diagram analysis of the end leakage flux is described. Moreover, the result of applying this method to a 60 Hz-1000 MW turbogenerator is also described
Keywords
magnetic fields; magnetic flux; magnetic leakage; stators; turbogenerators; 1000 MW; 60 Hz; electrical machines; electromagnetic behavior; end leakage flux; large turbogenerators; leakage flux evaluation; losses estimation; magnetic field analysis; phasor diagram analysis; stator core end region; temperature rise; three-dimensional magnetic field analysis; Flanges; Magnetic analysis; Magnetic cores; Magnetic fields; Magnetic flux; Performance analysis; Saturation magnetization; Stator cores; Temperature; Turbogenerators;