• DocumentCode
    1398465
  • Title

    The long-term stability of fixed resistors

  • Author

    Church, H.F.

  • Volume
    107
  • Issue
    34
  • fYear
    1960
  • fDate
    7/1/1960 12:00:00 AM
  • Firstpage
    377
  • Lastpage
    385
  • Abstract
    The causes of long-term failure under practical conditions of use or storage of different types of fixed resistors commonly used in electronic equipment have been investigated. Some reported life tests have proceeded without interruption for almost four years. Carbon-composition (grade 2) resistors under load fail by slow thermal degradation of the resistive material. Drift of value may also occur if unloaded resistors of this type are stored in a damp atmosphere. Vitreous-enamelled wire-wound resistors made with fine wire may fail during tropical exposure both unloaded and especially when lightly loaded with direct current. This is owing to electro-chemical corrosion taking place at faults in the vitreous coating. High-stability cracked-carbon (grade 1) resistors may fail rapidly under light d.c. load by electro-chemical action if moisture condensation occurs and the protective paint or varnish coating is inadequate. Tests for long-term resistor stability are critically discussed.
  • Keywords
    electronic equipment; quality control; resistors;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part B: Electronic and Communication Engineering
  • Publisher
    iet
  • ISSN
    0369-8890
  • Type

    jour

  • DOI
    10.1049/pi-b-2.1960.0132
  • Filename
    5244205