DocumentCode
1400792
Title
Measurement of the shunt impedance of overcoupled klystron cavities
Author
Belohoubek, E.F.
Author_Institution
Radio Corporation of America, Princeton, USA
Volume
109
Issue
23
fYear
1962
fDate
5/15/1905 12:00:00 AM
Firstpage
718
Lastpage
722
Abstract
The paper describes a measurement method for the determination of the shunt impedance Zsh = (R0/Q0)QL for over-coupled klystron cavities by field measurements in the cavity gap and a slotted line connected to the output waveguide. Losses and possible field distortions introduced by the coupling network are taken into account. An experimental check was performed on a cavity for which the characteristic impedance R0/Q0 was computed exactly. Under carefully controlled conditions a measurement accuracy of 5% can be achieved. The application of the method to the measurement of the shunt impedance of a multiple-beam ring circuit that is heavily over-coupled to a concentric line is described.
Keywords
electric impedance measurement; klystrons;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part B: Electronic and Communication Engineering
Publisher
iet
ISSN
0369-8890
Type
jour
DOI
10.1049/pi-b-2.1962.0120
Filename
5244609
Link To Document