• DocumentCode
    1400805
  • Title

    Sizing PZT Transducers in Impedance-Based Structural Health Monitoring

  • Author

    Baptista, Fabricio G. ; Filho, Jozue Vieira ; Inman, Daniel J.

  • Author_Institution
    Capes Found., Minist. of Educ. of Brazil, Brasília, Brazil
  • Volume
    11
  • Issue
    6
  • fYear
    2011
  • fDate
    6/1/2011 12:00:00 AM
  • Firstpage
    1405
  • Lastpage
    1414
  • Abstract
    A theoretical and experimental analysis regarding the correct size of PZT (Lead Zirconate Titanate) transducers used in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique is presented. Tests were carried out on aluminum structures using 5A and 5H PZT patches of various sizes. The results show that the sensitivity of SHM systems for damage detection can be optimized if the transducers are correctly sized according to the proposed procedure.
  • Keywords
    condition monitoring; electric impedance; piezoelectric transducers; PZT transducers; electromechanical impedance technique; impedance-based structural health monitoring; Electromagnetic interference; Frequency measurement; Impedance; Impedance measurement; Indexes; Sensitivity; Transducers; Electromechanical impedance; PZT ceramics; structural engineering; structural health monitoring (SHM);
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2010.2098865
  • Filename
    5664753