• DocumentCode
    1402050
  • Title

    Loosely power flow control scheme for piezoelectric energy harvesting

  • Author

    Lee, Chi Kwan ; Chan, P.K.W. ; Or, Siu Wing

  • Author_Institution
    Dept. of Electr. Eng., Hong Kong Polytech. Univ., Kowloon, China
  • Volume
    46
  • Issue
    25
  • fYear
    2010
  • Firstpage
    1689
  • Lastpage
    1691
  • Abstract
    Piezoelectric energy harvesting generally employs a maximum power point tracking (MPPT) control scheme in the DC-to-DC converter in order to continuously track to the maximum power point (MPP) voltage of the piezoelectric energy harvester (PEH). Owing to the high power consumption of the MPPT-based control circuit, the efficiency of the converter remains at an essentially low level. Proposed is a loosely power flow (LPF) control scheme to intermittently operate the converter near the MPP voltage of the PEH. Experimental verification on a 22 W PEH prototype finds that the power consumption of the LPF-based control circuit is as low as the quiescent power of the converter and the efficiency of the converter is as high as 56 .
  • Keywords
    energy harvesting; load flow control; maximum power point trackers; power consumption; DC-to-DC converter; loosely power flow control; maximum power point tracking control; piezoelectric energy harvesting; power consumption; quiescent power;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el.2010.2515
  • Filename
    5665838