Title :
Non-invasive electrohysterogram recording using flexible concentric ring electrode
Author :
Ye-Lin, Y. ; Alberola-Rubio, J. ; Prats-Boluda, Gema ; Bueno Barrachina, J.M. ; Perales, A. ; Valero, J. ; Desantes, D. ; Garcia-Casado, Javier
Author_Institution :
Grupo de Bioelectronica (I3BH), Univ. Politec. de Valencia, Valencia, Spain
Abstract :
Non-invasive electrohysterogram (EHG) recording could provide valuable information about uterine dynamics. Bipolar EHG has usually been performed using monopolar disposable electrodes. Recently concentric ring electrodes have been used for EHG recordings so as to acquire more localized electrical activity which may be helpful for deducing uterine contraction efficiency. Nevertheless concentric ring electrodes have commonly been implemented in rigid substrates. Therefore they do not adapt to the body surface curvature which may cause discomfort for patients and a poor contact between electrode and skin. The aim of this paper is to examine the feasibility of picking up EHG signals (BC-EHG) using a new flexible tripolar concentric ring (TCR) electrode placed on the abdominal surface, and to compare it with the conventional bipolar recordings. For this purpose, a total of 7 recording sessions were carried out in 7 pregnant women. Each recording implied simultaneous acquisition of one bipolar EHG signal and of two bipolar concentric EHG (BC-EHG) signals using the flexible TCR electrode. Then a set of temporal and spectral parameters was computed from both bipolar EHG and BC-EHG bursts. Experimental results show no noticeable difference in duration and in dominant frequency in Fast Wave High frequency range. Nonetheless, the low frequency content (0.1-0.2 Hz) of BC-EHG records is smaller than that of bipolar record. These results suggest that the new flexible TCR electrode permits to pick up uterine electrical activity and may provide additional information for deducing uterine efficiency.
Keywords :
bioelectric phenomena; biomedical electrodes; medical signal detection; obstetrics; patient diagnosis; skin; BC-EHG bursts; BC-EHG record; EHG recording; Fast Wave High frequency range; abdominal surface; bipolar EHG signal; bipolar concentric EHG signals; body surface curvature; conventional bipolar recording; dominant frequency; flexible TCR electrode; flexible concentric ring electrode; flexible tripolar concentric ring electrode; frequency 0.1 Hz to 0.2 Hz; localized electrical activity; monopolar disposable electrode; noninvasive electrohysterogram recording; pregnant women; recording sessions; rigid substrates; simultaneous acquisition; skin; spectral parameters; temporal parameters; uterine contraction efficiency; uterine dynamics; uterine efficiency; uterine electrical activity; Electric potential; Electrodes; Electromyography; Monitoring; Pregnancy; Skin; Substrates;
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
DOI :
10.1109/EMBC.2014.6944513