• DocumentCode
    1402974
  • Title

    A new form of electrolytic tank

  • Author

    Sander, K.F. ; Yates, J.G.

  • Volume
    104
  • Issue
    5
  • fYear
    1957
  • fDate
    3/1/1957 12:00:00 AM
  • Firstpage
    81
  • Lastpage
    86
  • Abstract
    The chief cause of erratic results when field gradients are measured in an electrolytic tank by means of closely spaced probes is shown to be variability of the meniscus near the probes. A new form of tank is described in which measurements are made by capillary probes in a plane defined by an insulating surface, thereby eliminating the meniscus effects present when the probes are placed in a free surface.
  • Keywords
    electrolytic devices; tanks (containers);
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part C: Monographs
  • Publisher
    iet
  • ISSN
    0369-8904
  • Type

    jour

  • DOI
    10.1049/pi-c.1957.0010
  • Filename
    5245080