DocumentCode
1403323
Title
Peak-voltage measurements of standard impulse voltage waves
Author
Aked, A.
Volume
103
Issue
3
fYear
1956
fDate
3/1/1956 12:00:00 AM
Firstpage
186
Lastpage
189
Abstract
The frequency spectrum of a 1/50 microsec impulse wave is obtained by the use of the Fourier transform. The corresponding frequency spectrum of the output from a simple capacitance potential divider, suitable for use up to 300 kV, is calculated from the input frequency spectrum for a 1/50 microsec wave and the frequency response of the divider, measured up to about 3 Mc/s. From this output frequency spectrum the output at a time of 1 microsec is calculated, and thus the divider ratio, suitable for peak-voltage measurements, is estimated. Consideration is given to errors due to the limited frequency range of the measurements, and the accuracy of the measurement of the divider ratio is estimated to be better than ±1%.
Keywords
transients; voltage measurement;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part C: Monographs
Publisher
iet
ISSN
0369-8904
Type
jour
DOI
10.1049/pi-c.1956.0022
Filename
5245155
Link To Document