• DocumentCode
    1406088
  • Title

    Characteristic Errors of a Loaded Synchro Transmitter

  • Author

    Farhi, Sivy

  • Author_Institution
    Infrared Laboratories, Hughes Aircraft Company, Culver City, Calif.
  • Volume
    83
  • Issue
    75
  • fYear
    1964
  • Firstpage
    439
  • Lastpage
    443
  • Abstract
    In this paper, the author accurately describes the characteristic error of a synchro transmitter which results from loading the secondary windings. The second harmonic error resulting from unbalanced loads has long been apparent to synchro manufacturers and users and has already been described.1 The secondary slot-harmonic error considered in this paper was predicted by the author while he was employed by the Eclipse-Pioneer Division of the Bendix Corporation. The existence of this error is not generally known, and its description has not been previously published. It is also shown that the minimum requirements for winding distributions are not the same in loaded and unloaded operation.
  • Keywords
    Bonding; Clamps; Equations; Impedance; Instruments; Jacobian matrices; Optimal control; Pulp manufacturing; Radio transmitters;
  • fLanguage
    English
  • Journal_Title
    Applications and Industry, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0536-1524
  • Type

    jour

  • DOI
    10.1109/TAI.1964.5407719
  • Filename
    5407719