DocumentCode
1406175
Title
Skewed slots in induction motors
Author
Ball, R. D.
Volume
50
Issue
12
fYear
1931
Firstpage
941
Lastpage
942
Abstract
INDUCTION MOTOR slots are usually skewed to prevent “cogging” and noise on load, but indiscriminate skew irrespective of number of poles, especially when this number is large, leads to very large reduction of short circuit current and motor performance. The reduction of short circuit current is due not so much to increase of leakage reactance as to an unbalanced component of mutual flux.
Keywords
Companies; Equations; Harmonic analysis; Induction motors; Magnetic flux; Short circuit currents; Windings;