DocumentCode :
1408438
Title :
Reusable Ultrasonic Tissue Mimicking Hydrogels Containing Nonionic Surface-Active Agents for Visualizing Thermal Lesions
Author :
Park, Seong Keun ; Guntur, S. R Anjaneya Reddy ; Lee, Kang Il ; Paeng, Dong-Guk ; Choi, Min Joo
Author_Institution :
Dept. of Biomed. Eng., Seoul Nat. Univ., Seoul, South Korea
Volume :
57
Issue :
1
fYear :
2010
Firstpage :
194
Lastpage :
202
Abstract :
The present study aims to identify a new recipe for reusable tissue mimicking phantoms that allows the optical visualization of thermal lesions produced in various applications of therapeutic ultrasound where thermal mechanisms are important. The phantom was made of polyacrylamide hydrogel containing a nonionic surface-active agent (NiSAA) as a temperature-sensitive indicator. Threshold temperature above which a thermal lesion is regarded to be formed in the phantom is controlled by selecting an NiSAA. In the present study, three NiSAAs of polyoxyethylene alkyl ether series with nominal clouding points of 66??C, 70??C, and 80??C were chosen. Test phantoms were prepared with polyacrylamide hydrogel, corn syrup and NiSAAs [5% (w/v)]. Key acoustic properties of the three NiSAA hydrogels were found to be similar to those of human liver. The phantoms were optically transparent at room temperature (25??C) and became opaque after exceeding the clouding points. The transparency was recovered on cooling, although the system demonstrated hysteresis. The phantoms were tested both in their ability to provide visualization of thermal lesions produced by high-intensity focused ultrasound and also to examine any characteristic differences in the shape of the lesions formed at different threshold temperatures. The present study suggests that the NiSAA polyacrylamide hydrogel will be of a practical use in quality assurance in various applications of therapeutic ultrasound where thermal mechanisms are important.
Keywords :
biomedical materials; biomedical ultrasonics; hydrogels; liver; phantoms; polymers; tissue engineering; high intensity focused ultrasound; human liver; nonionic surface active agents; optical visualization; reusable ultrasonic tissue mimicking hydrogels; temperature 293 K to 298 K; temperature 66 degC; temperature 70 degC; temperature 80 degC; therapeutic ultrasound; thermal lesion visualization; Acoustic testing; Cooling; Humans; Hysteresis; Imaging phantoms; Lesions; Liver; Temperature control; Ultrasonic imaging; Visualization; High-intensity focused ultrasound (HIFU); nonionic surface-active agent (NiSAA); polyacrylamide hydrogel; thermal lesion; tissue mimicking phantom; visualization; Acrylic Resins; Equipment Reuse; High-Intensity Focused Ultrasound Ablation; Humans; Hydrogels; Liver; Osmolar Concentration; Phantoms, Imaging; Surface-Active Agents; Temperature;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2009.2031314
Filename :
5247084
Link To Document :