• DocumentCode
    1408726
  • Title

    A new peak detection method for the three-phase sinusoidal signals

  • Author

    Wu, Kuen-Der ; Jou, Hurng-Liahng

  • Author_Institution
    Dept. of Electr. Eng., Nat. Kaohsiung Inst. of Technol., Taiwan
  • Volume
    45
  • Issue
    4
  • fYear
    1998
  • fDate
    8/1/1998 12:00:00 AM
  • Firstpage
    579
  • Lastpage
    584
  • Abstract
    An instantaneous amplitude detection method for the three-phase sinusoidal signals is proposed. The proposed method can measure the amplitude of the three-phase signals without any delay by using only two of the three-phase signals. The performance of this method under the ideal and nonideal conditions is analyzed. To demonstrate the performance of the proposed method, an electronic circuit for implementing this method is developed and tested
  • Keywords
    electric current measurement; industrial power systems; power system measurement; signal detection; transient response; voltage measurement; amplitude measurement; electronic circuit; ideal conditions; industrial power system; instantaneous amplitude detection method; nonideal conditions; peak detection method; performance; three-phase sinusoidal signals; transient response; Circuit testing; Delay; Detectors; Electronic circuits; Frequency; Power system transients; Regulators; Transient response; Uninterruptible power systems; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/41.704885
  • Filename
    704885