• DocumentCode
    1409828
  • Title

    Fast-Response Total Thermal Radiation Detectors

  • Author

    Wood, Allen D. ; Andrews, J.C.

  • Author_Institution
    Lockheed Missiles and Space Company, Palo Alto, Calif.
  • Issue
    2
  • fYear
    1967
  • fDate
    3/1/1967 12:00:00 AM
  • Firstpage
    356
  • Lastpage
    367
  • Abstract
    The construction, calibration, and performance of thin-film heat-transfer gauges in a measurement of the total radiant intensity of air at superorbital entry conditions are discussed. It is shown that reliance on an electrical bridge calibration alone can cause erroneous results. Magnetic interference from the shock tube flow was identified and eliminated by model design and shielding. Thin-film gauges are shown to be fundamentally unsuited for total radiation measurements because of noise caused by vacuum ultraviolet irradiation. Pyroelectric thermal detectors avoid this difficulty and offer several other advantages over thin-film gauges. The basic equations and practical considerations in the use of pyroelectric gauges are discussed.
  • Keywords
    Bridges; Calibration; Electric shock; Interference elimination; Magnetic noise; Magnetic shielding; Noise measurement; Pyroelectricity; Radiation detectors; Transistors; Calibration; calorimeter; flash tubes; pyroelectric; shock tube; thermal radiation; thin-film gauges;
  • fLanguage
    English
  • Journal_Title
    Aerospace and Electronic Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9251
  • Type

    jour

  • DOI
    10.1109/TAES.1967.5408762
  • Filename
    5408762