A testbed to explore the optimal electrical stimulation parameters for suppressing inter-ictal spikes in human hippocampal slices
Author :
Min-Chi Hsiao ; Pen-Ning Yu ; Dong Song ; Liu, Charles Y. ; Heck, Christi N. ; Millett, David ; Berger, Theodore W.
Author_Institution :
Dept. of Biomed. Eng., Univ. of Southern California (USC), Los Angeles, CA, USA
fYear :
2014
fDate :
26-30 Aug. 2014
Firstpage :
5792
Lastpage :
5795
Abstract :
New interventions using neuromodulatory devices such as vagus nerve stimulation, deep brain stimulation and responsive neurostimulation are available or under study for the treatment of refractory epilepsy. Since the actual mechanisms of the onset and termination of the seizure are still unclear, most researchers or clinicians determine the optimal stimulation parameters through trial-and-error procedures. It is necessary to further explore what types of electrical stimulation parameters (these may include stimulation frequency, amplitude, duration, interval pattern, and location) constitute a set of optimal stimulation paradigms to suppress seizures. In a previous study, we developed an in vitro epilepsy model using hippocampal slices from patients suffering from mesial temporal lobe epilepsy. Using a planar multi-electrode array system, inter-ictal activity from human hippocampal slices was consistently recorded. In this study, we have further transferred this in vitro seizure model to a testbed for exploring the possible neurostimulation paradigms to inhibit inter-ictal spikes. The methodology used to collect the electrophysiological data, the approach to apply different electrical stimulation parameters to the slices are provided in this paper. The results show that this experimental testbed will provide a platform for testing the optimal stimulation parameters of seizure cessation. We expect this testbed will expedite the process for identifying the most effective parameters, and may ultimately be used to guide programming of new stimulating paradigms for neuromodulatory devices.
Keywords :
bioelectric phenomena; biomedical electrodes; brain; neurophysiology; patient treatment; deep brain stimulation; electrical stimulation parameters; electrophysiological data; hippocampal slices; human hippocampal slices; in vitro epilepsy model; in vitro seizure model; inter-ictal activity; inter-ictal spikes; mesial temporal lobe epilepsy; neuromodulatory devices; neurostimulation paradigms; planar multielectrode array system; refractory epilepsy treatment; seizure cessation; trial-and-error procedures; vagus nerve stimulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2014.6944944