DocumentCode :
1410958
Title :
Correlation recognition of a redundant 5-unit telegraph code
Author :
Rosie, A.M.
Volume :
110
Issue :
3
fYear :
1963
fDate :
3/1/1963 12:00:00 AM
Firstpage :
493
Lastpage :
500
Abstract :
A system is described for the recognition of the signals of a redundant 5-unit telegraph code using a correlation technique. The expected error rates of this system, when the signals are perturbed by Gaussian noise, are calculated and compared with experimental results obtained from equipment constructed. The theoretical and practical error rates agree, and are less than those obtained by feeding the perturbed signals directly to a teleprinter.
Keywords :
signalling; telegraph stations; telegraphy;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1963.0073
Filename :
5247560
Link To Document :
بازگشت