    Lightning impulse voltage breakdown characteristics of vacuum interrupters with contact gaps 10 to 50 mm

  • Author

    Zhang, Yingyao ; Liu, Zhiyuan ; Geng, Yingsan ; Yang, Lanjun ; Wang, Jimei

  • Author_Institution
    State Key Lab. of Electr. Insulation & Power Equip., Xi´´an Jiaotong Univ., Xi´´an, China
  • Volume
    18
  • Issue
    6
  • fYear
    2011
  • fDate
    12/1/2011 12:00:00 AM
  • Firstpage
    2123
  • Lastpage
    2130
  • Abstract
    The objective of this paper is to understand the standard lightning impulse voltage breakdown characteristics of vacuum interrupters with contact gaps 10 to 50 mm and how contact parameters influence the breakdown characteristics. The investigated contact parameters include contact diameter 75 and 60 mm, contact surface roughness 1.6 and 3.2 μ m, and contact radius of curvature 6 and 2 mm. Therefore we designed four high-voltage vacuum interrupters in the experiments. The vacuum interrupters were put into a porcelain envelope with SF6 gas as an external insulation of the vacuum interrupters. The contact gaps can be adjusted manually up to 50 mm. Positive polarity lightning impulse voltage (1.2/50 μs) was applied by an up-and-down method. Experimental results revealed the breakdown probability distributions followed Weibull distributions when the breakdown voltage saturated within the investigated contact gaps 10 to 50 mm. Within the contact gaps 10 to 50 mm, U50 of vacuum interrupter with contact radius of curvature 2 mm was higher than that of vacuum interrupter with contact radius of curvature 6 mm. And U50 of contact roughness 1.6 μm was close to that of contact roughness 3.2 μm. U50 of the contact diameter 60 mm was close to that of contact diameter 75 mm. And 50% breakdown voltage U50 depended on the contact gap d (10-50 mm) for four interrupters, can be expressed by an equation U50=kdα, where a is a power exponent; k denotes a coefficient which can be determined by experiments. And under our experimental condition, power α lay in a range of 0.6-0.7 for the four vacuum interrupters. The breakdown phenomenon could be due to the micro-particles.
  • Keywords
    SF6 insulation; Weibull distribution; electric breakdown; vacuum interrupters; SF6 gas; Weibull distributions; breakdown probability distributions; high-voltage vacuum interrupters; lightning impulse voltage breakdown characteristics; positive polarity lightning impulse voltage; radius 2 mm; radius 6 mm; size 10 mm to 50 mm; size 3.1 mum; size 75 mm to 60 mm; surface roughness; up-and-down method; Breakdown voltage; Electrodes; Interrupters; Rough surfaces; Surface roughness; Vacuum breakdown; Breakdown characteristics; Standard lighting impulse voltage; Vacuum interrupters; Weibull distributions;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2011.6118653
  • Filename
    6118653