• DocumentCode
    1413149
  • Title

    Neon tube characteristics

  • Author

    Lohman, R. W.

  • Author_Institution
    Consulting Engineer, Los Angeles, Calif.
  • Volume
    52
  • Issue
    5
  • fYear
    1933
  • fDate
    5/1/1933 12:00:00 AM
  • Firstpage
    304
  • Lastpage
    307
  • Abstract
    Information supplementing and confirming the studies of voltage and current waves in neon tubes published in a previous issue of ELECTRICAL ENGINEERING are presented herewith. It is shown that there is a peaked starting voltage at the beginning of each wave, the current is practically zero at this point, the time during which the current wave remains at zero is negligible for a properly processed tube, and flickering will occur if the current remains at zero for even one-third cycle. Information on transformer regulation also is given.
  • Keywords
    Electrical engineering; Electron tubes; Finite element methods; Power transformer insulation; Voltage control; Voltage fluctuations; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1933.6430717
  • Filename
    6430717