• DocumentCode
    141324
  • Title

    A structural framework for interpretation of four-electrode microimpedance spectra in cardiac tissue

  • Author

    Pollard, Andrew E. ; Barr, Roger C.

  • Author_Institution
    Dept. Biomed. Eng., Univ. of Alabama Birmingham, Birmingham, AL, USA
  • fYear
    2014
  • fDate
    26-30 Aug. 2014
  • Firstpage
    6467
  • Lastpage
    6470
  • Abstract
    Renewed interest in the four-electrode method for identification of passive electrical properties in cardiac tissue has been sparked by a recognition that measurements made with sensors in close proximity are frequency dependent. Therefore, resolution of four-electrode microimpedance spectra (4EMS) may provide an opportunity for routine identification of passive electrical properties for the interstitial and intracellular compartments using only interstitial access. The present study documents a structural framework in which the tissue resistivity (ρt) and reactivity (xt) that comprise spectra are computed using interstitial and intracellular microimpedance distributions that account for differences in compartment size, anisotropic electrical properties in each compartment and electrode separations. We used this framework to consider 4EMS development with relatively wide (d=1 mm) and fine (d=250 μm) electrode separations and sensors oriented along myocyte axes, across myocyte axes and intermediate between those axes.
  • Keywords
    bioelectric potentials; biological tissues; biomedical electrodes; biomedical measurement; cardiology; cellular biophysics; electric impedance measurement; electrical resistivity; geometry; signal resolution; 4EMS development; 4EMS resolution; anisotropic electrical properties; cardiac tissue passive electrical property identification; close proximity sensors; compartment size effect; distance 1 mm; distance 250 mum; electrode separations; four-electrode microimpedance spectra interpretation; frequency dependence; interstitial access; interstitial compartments; interstitial microimpedance distributions; intracellular compartments; intracellular microimpedance distributions; myocyte axis; sensor orientation; structural framework; tissue reactivity computation; tissue resistivity computation; Biomedical measurement; Biomembranes; Conductivity; Electrodes; Heart; Myocardium; Sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2014.6945109
  • Filename