Title :
Comparison of methods of stopping squirrel-cage induction motors
Author_Institution :
Westinghouse Electric and Manufacturing Company, Boston, Mass.
Abstract :
APPLICATION engineers frequently encounter the problem of choosing between the several available methods employed to stop a squirrel-cage induction motor quickly. To the best of the writer´s knowledge, little has been done to present data in such a way as to make it useful to draw direct comparisons between these schemes, discuss the advantages of each, and aid in the choice of the method best suited to a particular application. Such is the purpose of this paper.
Keywords :
Coils; Contactors; DC motors; Friction; Induction motors; Torque;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1938.6430915