DocumentCode
1415208
Title
Single-switch soft-switching electronic ballast with high input power factor
Author
Lin, C.-S. ; Chen, C.-L.
Author_Institution
Dept. of Electr. Eng., Nat. Taiwan Univ., Taipei, Taiwan
Volume
145
Issue
4
fYear
1998
fDate
7/1/1998 12:00:00 AM
Firstpage
345
Lastpage
350
Abstract
Design and analysis of a new single-switch soft-switching class-E electronic ballast with high input power factor is presented. Design equations for the optimum operating condition are derived and complete computer analysis performed. It is shown that low duty-cycle control of the class-E ballast can reduce the voltage stress of the controlled switch. A 40 W fluorescent lamp ballast is implemented and experimental recordings verify the analytical results
Keywords
bridge circuits; fluorescent lamps; lamp accessories; power factor correction; rectifying circuits; switching circuits; 40 W; bridge rectifier; class-E electronic ballast; computer analysis; fluorescent lamp ballast; high input power factor; low duty-cycle control; optimum operating condition; power factor correction; single-switch soft-switching electronic ballast; voltage stress reduction;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:19981802