• DocumentCode
    1415208
  • Title

    Single-switch soft-switching electronic ballast with high input power factor

  • Author

    Lin, C.-S. ; Chen, C.-L.

  • Author_Institution
    Dept. of Electr. Eng., Nat. Taiwan Univ., Taipei, Taiwan
  • Volume
    145
  • Issue
    4
  • fYear
    1998
  • fDate
    7/1/1998 12:00:00 AM
  • Firstpage
    345
  • Lastpage
    350
  • Abstract
    Design and analysis of a new single-switch soft-switching class-E electronic ballast with high input power factor is presented. Design equations for the optimum operating condition are derived and complete computer analysis performed. It is shown that low duty-cycle control of the class-E ballast can reduce the voltage stress of the controlled switch. A 40 W fluorescent lamp ballast is implemented and experimental recordings verify the analytical results
  • Keywords
    bridge circuits; fluorescent lamps; lamp accessories; power factor correction; rectifying circuits; switching circuits; 40 W; bridge rectifier; class-E electronic ballast; computer analysis; fluorescent lamp ballast; high input power factor; low duty-cycle control; optimum operating condition; power factor correction; single-switch soft-switching electronic ballast; voltage stress reduction;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2352
  • Type

    jour

  • DOI
    10.1049/ip-epa:19981802
  • Filename