• DocumentCode
    1415643
  • Title

    Effect of Barrel Material on Critical Current Measurements of High- {\\rm J}_{\\rm c} RRP {\\rm Nb}_{3}{\\rm </h1></div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Author</span></div><div class='col-12 col-md-9 leftDirection leftAlign'><h2 class='mb-0 fw-semibold'>Ghosh, Arup K.</h2></div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Author_Institution</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>Brookhaven Nat. Lab., Upton, NY, USA</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Volume</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>21</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Issue</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>3</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>fYear</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>2011</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>fDate</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>6/1/2011 12:00:00 AM</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Firstpage</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>2327</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Lastpage</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>2330</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Abstract</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>Nb<sub>3</sub>Sn strands extracted from a 20-strand rectangular Rutherford cable were reacted on either stainless steel or Ti-alloy barrels and the critical current, I<sub>c</sub> , in the field range of 8-11.5 T was measured on ITER-type barrels made from Ti-6Al-4V alloy, 304 stainless steel and G-10. Measurements on the “standard” Ti-alloy barrel using the test procedure employed at BNL are shown to reproduce I<sub>c</sub> for extracted strands to ±2%. The I<sub>c</sub> data for the sample mounted on the “standard” Ti-alloy are fit to the deviatoric strain scaling model developed for Nb<sub>3</sub>Sn by the University of Twente group using an arbitrary pre-strain. Using the parameters for this fit, the I<sub>c</sub> data for the other barrels are fitted by only adjusting the strain. Using this procedure, the strain difference due to the barrel material is determined. Assuming a thermal pre-strain of -0.2% for the sample measured on the Ti-alloy barrel, the use of stainless steel barrel increases the compressive strain by -0.07%, that of G-10 by -0.10%. With the wire soldered to the stainless steel barrel, the strain increases to -0.15%. Details of this study are presented.</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Keywords</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>electric current measurement; stainless steel; superconducting cables; 20-strand rectangular Rutherford cable; Ti-alloy barrels; barrel material; compressive strain; critical current measurements; deviatoric strain scaling model; stainless steel barrel; standard Ti-alloy barrel; thermal prestrain; Critical current; Current measurement; Materials; Steel; Strain; Temperature measurement; Wires; Critical current; niobium compounds; strain; super conducting filaments and wires;</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>fLanguage</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>English</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Journal_Title</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>Applied Superconductivity, IEEE Transactions on</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Publisher</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>ieee</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>ISSN</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>1051-8223</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Type</span></div><div class='col-12 col-md-9 leftDirection leftAlign'><h2 class='mb-0 fw-semibold'>jour</h2></div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>DOI</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>10.1109/TASC.2010.2094596</div></div>
        </li>
        <li class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center mb-2'><div class='col-12 col-md-3 fullRecLabelEnglish fw-bold mb-2 mb-md-0'><span class='text-muted small'>Filename</span></div><div class='col-12 col-md-9 leftDirection leftAlign'>5677563</div></div>
        </li>
        <div class='list-group-item border-0 py-3 px-0'>
            <div class='row g-0 align-items-center'><div class='col-12 col-md-3 fw-bold mb-2 mb-md-0'><span class='text-muted small'>Link To Document</span></div><div class='col-12 col-md-9 leftDirection leftAlign'><a class='text-break' href='https://search.isc.ac/dl/search/defaultta.aspx?DTC=49&DC=1415643' target='_blank' rel=https://search.isc.ac/dl/search/defaultta.aspx?DTC=49&DC=1415643