DocumentCode :
1415838
Title :
The rating of resistance-welding transformers
Author :
Heitman, C. E.
Author_Institution :
Edward G. Budd Manufacturing Company, Philadelphia, Pa.
Volume :
57
Issue :
3
fYear :
1938
fDate :
3/1/1938 12:00:00 AM
Firstpage :
125
Lastpage :
130
Abstract :
The present method of rating resistance-welding transformers varies with the different manufacturers, causing a certain amount of confusion among the users of this equipment. It is recommended that a standard method of rating, based on the thermally equivalent continuous output, be adopted and adhered to by the manufacturers. The general requirements of a welding transformer are discussed for the purpose of explaining the desirability of such a standard rating. Certain of the recommendations made herein are already embodied in the present AIEE Standards for resistance welding apparatus, and in the standards adopted by the Resistance Welder Manufacturers Association, but it is further recommended that these standards be altered to require additional name plate data. It is hoped that the transformer manufacturers and users will recognize the desirability of such standardization, and co-operate in its universal adoption.
Keywords :
Circuit faults; Current transformers; Heating; Impedance; Power transformer insulation; Standards; Welding;