• DocumentCode
    1416115
  • Title

    Interpretation of oscillograms of arc-welding generators in terms of welding performance

  • Author

    Hansen, K. L.

  • Author_Institution
    Harnischfeger Corporation, Milwaukee, Wis.
  • Volume
    57
  • Issue
    4
  • fYear
    1938
  • fDate
    4/1/1938 12:00:00 AM
  • Firstpage
    177
  • Lastpage
    182
  • Abstract
    IT HAS long been recognized that the transient performance of an arc-welding generator greatly exceeds its static performance in importance. By transient performance is meant the behavior of the machine during the period of readjustment after a disturbance has taken place in the external circuit. Unlike most generators, an arc-welding generator supplies energy to a load in which conditions are continually changing, and the importance of the machine´s ability to respond quickly to these rapid variations is obvious.
  • Keywords
    Fluctuations; Generators; Inductance; Metals; Resistance; Transient analysis; Welding;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1938.6431232
  • Filename
    6431232