DocumentCode :
1416182
Title :
Impulse breakdown of short rod-plane gaps and the influence of humidity
Author :
Mikropoulos, P.N. ; Stassinopoulos, C.A.
Author_Institution :
Dept. of Electr. Eng. & Electron., Univ. of Manchester Inst. of Sci. & Technol., UK
Volume :
145
Issue :
4
fYear :
1998
fDate :
7/1/1998 12:00:00 AM
Firstpage :
141
Lastpage :
146
Abstract :
An attempt is made to assess the extent of influence of various parameters on the breakdown mechanism in short rod-plane gaps under positive impulses. Such parameters include front duration and peak value of the impulse voltage, gap length, profile of the rod and, in particular, absolute humidity. Depending on the above parameters, breakdown occurs either through a streamer-dominated breakdown mechanism or through one involving the development of a small leader. The second corona was found to predesignate which mechanism will take place, thus influencing the statistical behaviour of breakdown, Calculated humidity correction factors were found to be different from those proposed by IEC
Keywords :
air gaps; corona; electric breakdown; probability; transients; IEC standard; absolute humidity; breakdown mechanism; front duration; gap length; humidity correction factors; humidity influence; impulse breakdown; impulse voltage; peak value; positive impulses; predischarge phenomena; probability distributions; rod profile; second corona; short rod-plane gaps; small leader; statistical behaviour; streamer-dominated mechanism;
fLanguage :
English
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2344
Type :
jour
DOI :
10.1049/ip-smt:19982106
Filename :
707314
Link To Document :
بازگشت