Abstract :
This paper analyzes the performance of a three-phase induction generator which is connected to a single-phase power system. Significant improvement in machine performance can be obtained by using a single static phase-converter, provided that the machine is driven in the reverse direction. If two phase-converters, are employed, perfect phase balance can be obtained at any desired value of slip. The theoretical analysis is validated by experiments on a 2-kW test machine
Keywords :
AC-AC power convertors; asynchronous generators; machine testing; machine theory; phase convertors; power systems; slip (asynchronous machines); 2 kW; machine performance improvement; perfect phase balance; performance analysis; reverse direction driving; single static phase-converter; single-phase power system; slip; three-phase induction generator; Circuits; Induction generators; Induction machines; Performance analysis; Power system analysis computing; Reactive power; Renewable energy resources; Synchronous motors; Testing; Turbines;