• DocumentCode
    1419344
  • Title

    Charge and voltage characteristics of corona discharges in a coaxial geometry

  • Author

    Cooray, Vernon

  • Author_Institution
    Inst. of High Voltage Res.., Uppsala Univ., Sweden
  • Volume
    7
  • Issue
    6
  • fYear
    2000
  • fDate
    12/1/2000 12:00:00 AM
  • Firstpage
    734
  • Lastpage
    743
  • Abstract
    An engineering model is proposed to evaluate the variation of corona charge and corona current as a function of applied voltage for coaxial geometry (q-v curves). The two main assumptions of the model are the following: for streamer discharges to propagate continuously, the background field must be at, or just above, a critical level; and the streamers maintain a constant voltage gradient in the corona sheath. The model simulations are compared with the experimental q-v curves and a reasonable agreement is obtained between them
  • Keywords
    corona; electrodes; space charge; background field; charge characteristics; coaxial geometry; constant voltage gradient; corona current; corona discharges; critical level; engineering model; model simulations; streamer discharges; voltage characteristics; Coaxial components; Conductors; Corona; Current measurement; Electrodes; Equations; Geometry; Predictive models; Solid modeling; Voltage;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/94.891983
  • Filename