DocumentCode :
1419479
Title :
Energy efficiency improvement of electrical sterilization using oscillatory waveforms from a RLC discharging circuit
Author :
Lee, Duck-Chul ; Suehiro, Junya ; Hara, Masanori ; Duck-Chul Lee ; So, Myung-Hwan
Author_Institution :
Dept. of Electron. Eng., Bucheon Coll., South Korea
Volume :
7
Issue :
6
fYear :
2000
fDate :
12/1/2000 12:00:00 AM
Firstpage :
872
Lastpage :
874
Abstract :
This paper describes effects of pulsed HV waveforms on biological cell inactivation. A simple RLC circuit with various inductance values was employed to investigate the waveform effects on the electrical sterilization of Escherichia Coli. It has been found that the minimum value of cell survivability can be realized by choosing an appropriate inductance value, even when the initial energy stored in a capacitor is constant. In order to realize higher energy efficiency than a conventional RC discharging network, circuit parameters should be determined so that amplitude and width of each pulse becomes larger than the critical values 15 kV/cm and 50 μs, respectively
Keywords :
biological effects of fields; cellular effects of radiation; food processing industry; microorganisms; Escherichia Coli; RLC discharging circuit; biological cell inactivation; cell survivability; circuit parameters; electrical sterilization; energy efficiency; inductance value; inductance values; oscillatory waveforms; pulsed HV waveforms; waveform effects; Biological cells; Capacitors; Electric resistance; Energy efficiency; Immune system; Inductance; Power engineering and energy; Pulse circuits; RLC circuits; Voltage;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/94.892003
Filename :
892003
Link To Document :