DocumentCode :
1420303
Title :
Microwave electrostatic wattmeter
Author :
Barlow, H.M. ; Wizner, W.W.
Author_Institution :
University College London, Department of Electrical Engineering, London, UK
Volume :
117
Issue :
1
fYear :
1970
fDate :
1/1/1970 12:00:00 AM
Firstpage :
249
Lastpage :
254
Abstract :
The paper describes a new instrument which operates as the microwave equivalent of the well known low-frequency electrostatic wattmeter. The torque on the moving vane depends on the forces arising simultaneously from both the electric and magnetic components of the field carrying the power, with the consequence that accurate measurements can be made for any standing-wave ration up to about 6 : 1. A theoretical analysis of the operation of the instrument, supported by experimental information derived from a model, shows the practicability of the design, particularly as a reference standard. Using a photovoltaic cell for recording small deflections, the wattmeter operating at Xband is capable of an accuracy of ±2% when measuring powers of about 100mW, and it may be calibrated on an absolute basis.
Keywords :
electrostatic devices; wattmeters;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1970.0055
Filename :
5249069
Link To Document :