• DocumentCode
    1421285
  • Title

    Suppression of magnetic vibration and noise of two-pole turbine generators

  • Author

    Penniman, A. L. ; Taylor, H. D.

  • Author_Institution
    Consolidated Gas Electric Light and Power Company of Baltimore
  • Volume
    60
  • Issue
    6
  • fYear
    1941
  • fDate
    6/1/1941 12:00:00 AM
  • Firstpage
    283
  • Lastpage
    288
  • Abstract
    The constant striving for improvement in over-all economy in the generation of electric power by steam has resulted in the last three or four years in a rather rapid increase in the capacity of steam turbine generators built to operate at 3,600 rpm. One of the factors contributing to this growth was the progress made in the use of high-pressure and high-temperature steam which led to the application of a number of such turbines for superposition on existing comparatively low-pressure steam plants, as well as for straight through condensing operation. The operating experience with such recently developed 3,600-rpm generators ranging in capacity up to 66,667 kva has been unusually good. The troubles which have been experienced, either mechanical or electrical, have not been of a serious nature.
  • Keywords
    Generators; Magnetic cores; Resonant frequency; Springs; Stator cores; Vibrations;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1941.6432150
  • Filename
    6432150