• DocumentCode
    1421623
  • Title

    A comparison between XLPE and EPR as insulating materials for HV cables

  • Author

    Mazzanti, G. ; Montanari, G.C.

  • Author_Institution
    Dipartimento di Ingegneria Elettrica, Bologna Univ., Italy
  • Volume
    12
  • Issue
    1
  • fYear
    1997
  • fDate
    1/1/1997 12:00:00 AM
  • Firstpage
    15
  • Lastpage
    28
  • Abstract
    The performances of XLPE and EPR as candidate materials for insulation of high voltage power cables are investigated. Data obtained from laboratory tests performed on cable models aged under single thermal and electrical stresses, as well as under the combination of the two stresses, are considered. The drawing of electrical, thermal and multi-stress life lines provides a synthetic and exhaustive description of the behavior of the tested materials, and allows the determination of endurance indices, useful for electrical, thermal and multi-stress characterization
  • Keywords
    XLPE insulation; ageing; ethylene-propylene rubber; insulation testing; power cable insulation; power cable testing; power cables; thermal stresses; EPR; HV cables; XLPE; electrical stresses; endurance indices; high voltage power cables; insulating materials; laboratory tests; multi-stress life lines; thermal stresses; Aging; Cable insulation; Communication cables; Laboratories; Paramagnetic resonance; Performance evaluation; Power cables; Testing; Thermal stresses; Voltage;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/61.568220
  • Filename
    568220