  • Abstract
    The paper presents the investigated results of performance of power transformers when used for converters supply of DC drive of hosting machines. Particular attention was paid on the power loss due to deformed current and voltage waveforms. The active and reactive power losses were compared for the newly employed transformer to this working more that 16 years. On the basis of the measurements the conclusions and recommendations for use in practice are formulated.
  • Keywords
    DC motor drives; harmonics; hoists; losses; power convertors; power transformers; DC drive converter supply; deformed current waveforms; hoisting machines; power transformer; reactive power losses; Current measurement; Harmonic analysis; Power harmonic filters; Power transformer insulation; Reactive power; DC drive; Power transformer; high harmonics; hoisting machine; power loss;