DocumentCode :
1423391
Title :
Techniques for improved magnetic recording
Author :
Holmes, Lynn C.
Author_Institution :
Research Department, Engineering Division, Stromberg-Carlson Company, Rochester, N. Y.
Volume :
68
Issue :
10
fYear :
1949
Firstpage :
836
Lastpage :
841
Abstract :
This article describes some of the techniques which may be used to improve the frequency response, reduce the distortion, and increase the signal-to-noise ratio of magnetic recording systems. Also discussed are some new methods of measurements by which these improvements may be evaluated. The author believes the application of the techniques to practical systems will not necessarily follow immediately; however, magnetic recording is already well established in many fields of application and its future looks bright.
Keywords :
Acoustic distortion; Coils; Distortion measurement; Frequency response; Magnetic heads; Magnetic recording; Noise;
fLanguage :
English
Journal_Title :
Electrical Engineering
Publisher :
ieee
ISSN :
0095-9197
Type :
jour
DOI :
10.1109/EE.1949.6432501
Filename :
6432501
Link To Document :