• DocumentCode
    1424342
  • Title

    Automated Segmentation of Intraretinal Cystoid Fluid in Optical Coherence Tomography

  • Author

    Wilkins, Gary R. ; Houghton, Odette M. ; Oldenburg, Amy L.

  • Author_Institution
    Dept. of Phys. & Astron., Univ. of North Carolina at Chapel Hill, Chapel Hill, NC, USA
  • Volume
    59
  • Issue
    4
  • fYear
    2012
  • fDate
    4/1/2012 12:00:00 AM
  • Firstpage
    1109
  • Lastpage
    1114
  • Abstract
    Cystoid macular edema (CME) is observed in a variety of ocular disorders and is strongly associated with vision loss. Optical coherence tomography (OCT) provides excellent visualization of cystoid fluid, and can assist clinicians in monitoring the progression of CME. Quantitative tools for assessing CME may lead to better metrics for choosing treatment protocols. To address this need, this paper presents a fully automated retinal cyst segmentation technique for OCT image stacks acquired from a commercial scanner. The proposed method includes a computationally fast bilateral filter for speckle denoising while maintaining CME boundaries. The proposed technique was evaluated in images from 16 patients with vitreoretinal disease and three controls. The average sensitivity and specificity for the classification of cystoid regions in CME patients were found to be 91% and 96%, respectively, and the retinal volume occupied by cystoid fluid obtained by the algorithm was found to be accurate within a mean and median volume fraction of 1.9% and 0.8%, respectively.
  • Keywords
    biomedical optical imaging; eye; image denoising; image segmentation; medical image processing; optical tomography; speckle; vision defects; CME assessment; CME boundaries; CME progression monitoring; CME treatment protocols; OCT image stacks; commercial OCT scanner; computationally fast bilateral filter; cystoid fluid visualization; cystoid macular edema; fully automated retinal cyst segmentation technique; intraretinal cystoid fluid automated segmentation; ocular disorders; optical coherence tomography; speckle denoising; vision loss; Filtering; Fluids; Image segmentation; Noise reduction; Retina; Signal to noise ratio; Speckle; Biomedical imaging; computer-aided diagnosis; macular edema; optical coherence tomography (OCT); Algorithms; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Macular Edema; Pattern Recognition, Automated; Reproducibility of Results; Retinoscopy; Sensitivity and Specificity; Tomography, Optical Coherence;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2012.2184759
  • Filename
    6132458