DocumentCode
1425149
Title
Real-Time, Digital Pulse-Shape Discrimination in Non-Hazardous Fast Liquid Scintillation Detectors: Prospects for Safety and Security
Author
Joyce, Malcolm J. ; Aspinall, Michael D. ; Cave, Francis D. ; Lavietes, Anthony D.
Author_Institution
Engineering Department, Lancaster University, Lancaster, UK
Volume
59
Issue
4
fYear
2012
Firstpage
1245
Lastpage
1251
Abstract
Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and
rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/
-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flashpoint and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/
-ray separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of
events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous.
Keywords
Detectors; Graphical user interfaces; Helium; Instruments; Neutrons; Real-time systems; Instrumentation and measurement; neutrons; nuclear electronics; nuclear measurements;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2011.2174651
Filename
6133314