DocumentCode :
1425698
Title :
Review of test methods used for the measurement of hermeticity in packages containing small cavities
Author :
Costello, S. ; Desmulliez, Marc P Y ; McCracken, Stewart
Author_Institution :
Microsyst. Eng. Centre, Heriot-Watt Univ., Edinburgh, UK
Volume :
2
Issue :
3
fYear :
2012
fDate :
3/1/2012 12:00:00 AM
Firstpage :
430
Lastpage :
438
Abstract :
This paper presents a critical review of the traditional and newly proposed test methods used for the measurement of hermeticity in packages with very small cavity volumes. Closed-form expressions of the minimum and maximum true leak rates achievable are provided for the helium fine leak test method. These expressions are shown to provide practical guidelines for the accurate testing of hermeticity for ultrasmall packages. A portfolio of hermeticity test methods is also presented outlining the limitations and advantages of each method.
Keywords :
electron device testing; electronics packaging; hermetic seals; leak detection; closed-form expressions; helium fine leak test method; hermeticity measurement; hermeticity test method; leak detection; maximum true leak rates; minimum true leak rates; ultrasmall packages; Cavity resonators; Detectors; Helium; Packaging; Time measurement; Weapons; Hermeticity; leak detection; packaging; test;
fLanguage :
English
Journal_Title :
Components, Packaging and Manufacturing Technology, IEEE Transactions on
Publisher :
ieee
ISSN :
2156-3950
Type :
jour
DOI :
10.1109/TCPMT.2011.2176122
Filename :
6134641
Link To Document :
بازگشت