Title :
Elimination of astigmatism from a c.r.t. display
Author :
Bull, E.W. ; Galloway, R.de P.
fDate :
7/1/1964 12:00:00 AM
Abstract :
Simple expressions, suitable for design purposes, are deduced for the major aberrations due to the magnetic deflection of the convergent electron beam in a cathode-ray tube. These expressions are confirmed by measurements on a number of saddle and toroidal scanning coils. Conditions are derived for an anastigmatic display.
Keywords :
cathode-ray tubes; electron beams; television picture tubes;
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
DOI :
10.1049/piee.1964.0191