Title :
External thermal resistance of two buried cables. Restricted application of superposition
Author :
Goldenberg, H.
Author_Institution :
Electrical Research Association, Leatherhead, UK
Volume :
116
Issue :
5
fYear :
1969
fDate :
5/1/1969 12:00:00 AM
Firstpage :
822
Lastpage :
826
Abstract :
New formulas are derived for the external thermal resistance of one of two equally loaded identical cables laid direct in the ground at the same depth. The formulas are based on a restricted application of the principle of superposition, and remain valid when the cables are close or touching. Two assumptions made are that the depth of the buried cables is much greater than the cable radius, and that the cable surfaces are isothermal at a common temperature. The former assumption is justified as the cable depth is generally equal to at least ten times the cable radius. The latter assumption is recognised to be an approximation, but the present approach may prove to be more acceptable than alternative techniques. Comparison is made with previously published formulas.