DocumentCode :
1427858
Title :
Echocardiographic speckle reduction comparison
Author :
Finn, Seán ; Glavin, Martin ; Jones, Edward
Author_Institution :
Nat. Centre for Biomed. Eng. Sci., Nat. Univ. of Ireland Galway, Galway, Ireland
Volume :
58
Issue :
1
fYear :
2011
fDate :
1/1/2011 12:00:00 AM
Firstpage :
82
Lastpage :
101
Abstract :
In this paper, a detailed description and comparison of speckle reduction of medical ultrasound, and in particular echocardiography, is presented. Fifteen speckle reduction filters are described in a detailed fashion to facilitate implementation for research and evaluation. The filtering techniques considered include anisotropic diffusion, wavelet denoising, and local statistics. Common nomenclature and notation are adopted, to expedite comparison between approaches. Comparison of the filters is based on their application to simulated images, clinical videos, and a computational requirement analysis. The ultrasound simulation method provides a realistic model of the image acquisition process, and permits the use of a noise-free reference image for comparison. Application of objective quality metrics quantifies the preservation of image edges, overall image distortion, and improvement in image contrast. The computational analysis quantifies the number of operations required for each speckle reduction method. A speed-accuracy analysis of discretization methods for anisotropic diffusion is included. It is concluded that the optimal method is the OSRAD diffusion filter. This method is capable of strong speckle suppression, increasing the average SNRA of the simulated images by a factor of two. This method also shows favorable edge preservation and contrast improvement, and may be efficiently implemented.
Keywords :
biomedical ultrasonics; data acquisition; electrocardiography; image denoising; medical image processing; statistical analysis; wavelet transforms; OSRAD diffusion filter; anisotropic diffusion; computational requirement analysis; contrast improvement; discretization methods; echocardiography; edge preservation; filtering techniques; image acquisition process; local statistics; medical ultrasound; noise-free reference image; speckle reduction filters; speckle suppression; speed-accuracy analysis; wavelet denoising; Anisotropic magnetoresistance; Approximation methods; Computational modeling; Noise; Smoothing methods; Speckle; Ultrasonic imaging; Anisotropy; Artifacts; Computer Simulation; Contrast Media; Echocardiography; Humans; Nonlinear Dynamics; Signal Processing, Computer-Assisted; Wavelet Analysis;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2011.1776
Filename :
5688403
Link To Document :
بازگشت