Test Requirements and Performance Evaluation for Both Resistive and Inductive Superconducting Fault Current Limiters for 22.9 kV Electric Distribution Network in Korea
Author
Lee, B.W. ; Rhee, S.B.
Author_Institution
Sch. Electr. & Comput. Sci., Hanyang Univ., Ansan, South Korea
Volume
20
Issue
3
fYear
2010
fDate
6/1/2010 12:00:00 AM
Firstpage
1114
Lastpage
1117
Abstract
Enlarging the electric power supply capacity of 22.9 kV distribution line by upgrading the main transformer from 60 MVA to 100 MVA has been under consideration in order to cope with increasing electric power demands of distriution line in Korea which aims to replace some 154 kV supply demands by 22.9 kV large-capacity distribution systems. In this case, the prospective fault current of 22.9 kV distribution line is much bigger than the rated withstand fault current level of conventional electric equipments. As a major feasible solution to reduce excessive fault current, superconducting fault current limiters (SFCLs) are considered to be installed at 154 kV/22.9 kV substation. But until now, certified specifications or test procedures were not available considering utilities´ requirements. And the performances of various types of SFCLs were not deeply investigated regarding the reclosing scheme of conventional networks. In this paper, in order to determine the suitable type of SFCL for newly installed 22.9 kV large distribution line in Korea, requirements and specifications of SFCLs were proposed considering the installation spots of large-capacity distribution line. Four types of SFCLs were modeled and analyzed using EMTP and their performances focusing on the coordination with reclosers were investigated to verify the suitability into the large-capacity distribution line. Consequently, detailed specifications and expected installation sites were proposed and suitable types of SFCLs for 22.9 kV large-capacity distribution line were suggested.
Keywords
fault current limiters; power distribution lines; power system protection; Korea; distribution line; electric distribution network; electric power supply capacity; inductive superconducting fault current limiters; performance evaluation; resistive superconducting fault current limiters; test requirements; voltage 22.9 kV; 22.9 kV large-capacity distribution line; EMTP; hybrid SFCL; inductive SFCL; resistive SFCL;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/TASC.2010.2040256
Filename
5422717
Link To Document