DocumentCode
1430109
Title
The 50 kA Superconducting Transformer for Testing ITER CC Conductors Short Sample
Author
Shi, Yi ; Wu, Yu ; Wu, Songtao ; Liu, Huajun ; Peng, Jinqing
Author_Institution
Inst. of Plasma Phys., Chinese Acad. of Sci., Hefei, China
Volume
20
Issue
3
fYear
2010
fDate
6/1/2010 12:00:00 AM
Firstpage
1155
Lastpage
1158
Abstract
To meet the specification of International Thermonuclear Experimental Reactor (ITER) Correction Coil (CC) conductors, the 50 kA superconducting transformer has been designed which allows rating of conductor samples during different operating conditions at the Institute of Plasma Physics, the Chinese Academy of Sciences (ASIPP). The superconducting transformer consists of two concentric layer-wound superconducting solenoids with the primary inside the secondary. The 50 kA secondary conductor consists of 4 turns of rectangular cable-in-conduit conductor (CICC) type used of the 0.87 mm NbTi superconductor strands. This paper describes the basic principles of superconducting transformer, the designed concept of the 50 kA superconducting transformer.
Keywords
Tokamak devices; superconducting magnets; superconducting transformers; ITER CC conductors short sample; NbTi superconductor strands; concentric layer-wound superconducting solenoids; correction coil conductors; international thermonuclear experimental reactor; rectangular cable-in-conduit conductor; secondary conductor; superconducting transformer; CC; ITER; conductor; transformer;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/TASC.2010.2041210
Filename
5422871
Link To Document