• DocumentCode
    1430201
  • Title

    Effect of humidity on sparkover of airgaps under impulsive voltages

  • Author

    Allibone, T.E. ; Dring, D.

  • Author_Institution
    Leeds University, Department of Electrical & Electronic Engineering, Leeds, UK
  • Volume
    121
  • Issue
    3
  • fYear
    1974
  • fDate
    3/1/1974 12:00:00 AM
  • Firstpage
    221
  • Lastpage
    222
  • Abstract
    The influence of high humidity on the sparkover of a 40 cm square-ended rod-rod gap and round-ended rod-plane gap has been studied using impulse voltages of +1/1000 ¿S waveshape. Over the large humidity range 7¿27 g/m3 achieved, it was found that, for each increase of 1 g/m3 of water vapour, a corresponding increase in the mean sparkover voltage of 1% for the rod-rod gap and 1.25% for the rod-plane gap was obtained.