• DocumentCode
    1430708
  • Title

    Testing steam turbine generator governors under system load conditions

  • Author

    Tornquist, E. L. ; Wade, I. L.

  • Author_Institution
    Public Service Company of Northern Illinois, Chicago, Ill
  • Volume
    69
  • Issue
    3
  • fYear
    1950
  • fDate
    3/1/1950 12:00:00 AM
  • Firstpage
    225
  • Lastpage
    229
  • Abstract
    STEAM TURBINE governors must be tested to determine performance of a governor with respect to purchase specifications, to determine the necessity for and the results of maintenance work on the governor, and to determine the optimum settings of the governor through a knowledge of the governor characteristics and system requirements in order that each unit will perform most satisfactorily considering its size, heat rate, location on the system, and local plant steam generating conditions. If the need is only for determining conformance to specifications, elaborate equipment can be used, but to be used effectively in the maintenance and operation of the governor the equipment should be simple to operate and provide the necessary data quickly.
  • Keywords
    Bridge circuits; Cable shielding; Generators; IEEE transactions; Power cables; Turbines; Valves;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1950.6433733
  • Filename
    6433733