DocumentCode
1430708
Title
Testing steam turbine generator governors under system load conditions
Author
Tornquist, E. L. ; Wade, I. L.
Author_Institution
Public Service Company of Northern Illinois, Chicago, Ill
Volume
69
Issue
3
fYear
1950
fDate
3/1/1950 12:00:00 AM
Firstpage
225
Lastpage
229
Abstract
STEAM TURBINE governors must be tested to determine performance of a governor with respect to purchase specifications, to determine the necessity for and the results of maintenance work on the governor, and to determine the optimum settings of the governor through a knowledge of the governor characteristics and system requirements in order that each unit will perform most satisfactorily considering its size, heat rate, location on the system, and local plant steam generating conditions. If the need is only for determining conformance to specifications, elaborate equipment can be used, but to be used effectively in the maintenance and operation of the governor the equipment should be simple to operate and provide the necessary data quickly.
Keywords
Bridge circuits; Cable shielding; Generators; IEEE transactions; Power cables; Turbines; Valves;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1950.6433733
Filename
6433733
Link To Document