DocumentCode
1431811
Title
Spark ignition probability estimates for resistor and inductor circuits in methane-air atmospheres
Author
Cawley, James C.
Author_Institution
US Bur. of Mines, Pittsburgh Res. Center, PA, USA
Volume
24
Issue
5
fYear
1988
Firstpage
878
Lastpage
883
Abstract
The safety factor presently used by the US Mine Safety and Health Administration to assess the safety of electronic circuits for use in methane-air atmospheres is a factor of 1.5 on energy at the point of test plus two worst-case faults. The Bureau of Mines is engaged in intrinsic safety research that will ultimately relate the conditions of test and actual use by estimating the simple ignition probability, versus current for circuits in an 8.3% methane-air atmosphere. The experimental design minimizes the probability of not observing an ignition that should occur during a series of tests. For resistive circuits, no ignitions were observed below 2000 mA at 20 V DC, 350 mA at 30 V DC, 150 mA at 40 V DC, and 175 mA at 50 V DC. Results for inductive circuits show that ignition was not obtained below 35 mA for 600 mH, 90 mA for 100 mH, 230 mA for 10 mH, and 700 mA for 1 mH. These results imply that a threshold value exists below which spark ignition does not occur
Keywords
ignition; mining; probability; safety; sparks; 150 mA; 170 mA; 20 V; 2000 mA; 230 mA; 30 V; 35 mA; 350 mA; 40 V; 50 V; 700 mA; 90 mA; USA; electronic circuits; ignition probability; inductive circuits; methane-air atmospheres; mining; resistive circuits; safety; spark ignition; Atmosphere; Circuit faults; Circuit testing; Electronic circuits; Electronic equipment testing; Health and safety; Ignition; Inductors; Resistors; Sparks;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.8994
Filename
8994
Link To Document