DocumentCode :
1431855
Title :
Non-Contact Measurement of Current Distribution in Striated CTCC
Author :
Han, B.-W. ; Park, S.H. ; Kim, W.-S. ; Lee, J.K. ; Lee, S. ; Byun, S.B. ; Park, C. ; Lee, B.W. ; Choi, K. ; Hahn, S.
Author_Institution :
Korea Polytech. Univ., Shiheung, South Korea
Volume :
20
Issue :
3
fYear :
2010
fDate :
6/1/2010 12:00:00 AM
Firstpage :
1952
Lastpage :
1955
Abstract :
We have proposed continuously transposed coated conductor (CTCC) in striation for power devices reducing AC loss. It consists of a number of coated conductors with filaments made by striation. The transport of current may distribute non-uniformity in the filament particularly while CTCC conducts AC current. The array of Hall sensors is capable of measuring the current distribution in the filaments and in conductors. However, the search coil array may be applied as ersatz for Hall array in case of existing AC current. The filamentary CTCCs are prepared and the current distribution is then measured by the array of search coils.
Keywords :
conductors (electric); current distribution; superconducting devices; AC loss; Hall array; Hall sensors; coated conductors; continuously transposed coated conductor; current distribution; filaments; noncontact measurement; power devices; striated CTCC; AC loss; continuously transposed coated conductor (CTCC); current distribution; search coil; striation;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2009.2039930
Filename :
5424085
Link To Document :
بازگشت