Title :
Measurements of High-Frequency (2–150 kHz) Distortion in Low-Voltage Networks
Author :
Larsson, E. O Anders ; Bollen, Math H J ; Wahlberg, Mats G. ; Lundmark, C. Martin ; Rönnberg, Sarah K.
Author_Institution :
Skelleftea Dept., Lulea Univ. of Technol., Skelleftea, Sweden
Volume :
25
Issue :
3
fYear :
2010
fDate :
7/1/2010 12:00:00 AM
Firstpage :
1749
Lastpage :
1757
Abstract :
This paper presents different methods to describe voltage and current distortion in the frequency range 2 to 150 kHz. The time-frequency domain was shown to give additional information next to the time- and frequency-domain representations. Measurements of different devices and at different locations showed remnants of the switching frequency of the power electronics as well as lower frequency oscillations around the current zero crossing to be present in voltage and current. The voltage distortion is shown to vary a lot during the day and between locations.
Keywords :
distortion; distortion measurement; power system harmonics; switched mode power supplies; time-frequency analysis; current distortion; electromagnetic compatibility; frequency 2 kHz to 150 kHz; high-frequency distortion measurement; low frequency oscillations; low-voltage networks; power electronics; power quality; power system harmonics; switched-mode power supplies; switching frequency; time-frequency domain; voltage distortion; Electromagnetic compatibility (EMC); power quality (PQ); power system harmonics; switched-mode power supplies;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/TPWRD.2010.2041371
Filename :
5424121
Link To Document :
بازگشت