Abstract :
An electrode biasing system was designed, constructed, and installed on the IR-T1 tokamak, and then, the positive voltage applied to an electrode inserted inside the tokamak limiter and the plasma current, poloidal and radial components of the magnetic fields, loop voltage, diamagnetic flux, and ion saturation currents in the absence and presence of the biased electrode were measured. Results of measurements of biasing effects on the plasma equilibrium behavior and edge plasma rotation are compared and discussed.
Keywords :
Tokamak devices; electrodes; plasma flow; plasma toroidal confinement; plasma transport processes; IR-T1 tokamak; biasing effects; diamagnetic flux; edge plasma rotation; electrode biasing system; ion saturation currents; loop voltage; magnetic fields; plasma current; plasma equilibrium behavior; poloidal component; positive voltage; radial component; tokamak limiter; Current measurement; Electrodes; Plasma measurements; Probes; Saturation magnetization; Tokamaks; Electrode biasing system; tokamak;