• DocumentCode
    1433311
  • Title

    Closed-Form Inverse Kinematics for Interventional C-Arm X-Ray Imaging With Six Degrees of Freedom: Modeling and Application

  • Author

    Wang, Lejing ; Fallavollita, Pascal ; Zou, Rui ; Chen, Xin ; Weidert, Simon ; Navab, Nassir

  • Author_Institution
    Dept. of Comput. Aided Med. Procedures, Tech. Univ. of Munich, Munich, Germany
  • Volume
    31
  • Issue
    5
  • fYear
    2012
  • fDate
    5/1/2012 12:00:00 AM
  • Firstpage
    1086
  • Lastpage
    1099
  • Abstract
    For trauma and orthopedic surgery, maneuvering a mobile C-arm fluoroscope into a desired position to acquire an X-ray is a routine surgical task. The precision and ease of use of the C-arm becomes even more important for advanced interventional imaging techniques such as parallax-free X-ray image stitching. Today´s standard mobile C-arms have been modeled with only five degrees of freedom (DOF), which definitely restricts their motions in 3-D Cartesian space. In this paper, we present a method to model both the mobile C-arm and patient´s table as an integrated kinematic chain having six DOF without constraining table position. The closed-form solutions for the inverse kinematics problem are derived in order to obtain the required values for all C-arm joint and table movements to position the fluoroscope at a desired pose. The modeling method and the closed-form solutions can be applied to general isocentric or nonisocentric mobile C-arms. By achieving this we develop an efficient and intuitive inverse kinematics-based method for parallax-free panoramic X-ray imaging. In addition, we implement a 6-DOF C-arm system from a low-cost mobile fluoroscope to optimally acquire X-ray images based solely on the computation of the required movement for each joint by solving the inverse kinematics on a continuous basis. Through simulation experimentation, we demonstrate that the 6-DOF C-arm model has a larger working space than the 5-DOF model. C-arm repositioning experiments show the practicality and accuracy of our 6-DOF C-arm system. We also evaluate the novel parallax-free X-ray stitching method on phantom and dry bones. Using five trials, results show that parallax-free panoramas generated by our method are of high visual quality and within clinical tolerances for accurate evaluation of long bone geometry (i.e., image and metric measurement errors are less than 1% compared to ground-truth).
  • Keywords
    CAD; bone; diagnostic radiography; medical robotics; orthopaedics; phantoms; surgery; 3-D Cartesian space; 6-DOF C-arm system; advanced interventional imaging techniques; bone geometry; clinical tolerance; closed-form inverse kinematics; closed-form solutions; dry bones; integrated kinematic chain; interventional C-arm X-ray imaging; inverse kinematics problem; isocentric mobile C-arms; joint movements; low-cost mobile fluoroscope; metric measurement errors; mobile C-arm fluoroscope; nonisocentric mobile C-arms; orthopedic surgery; parallax-free X-ray image stitching; parallax-free panoramas; phantom; routine surgical task; six degrees-of-freedom; standard mobile C-arms; table movements; trauma; Closed-form solutions; Joints; Kinematics; Mathematical model; Mobile communication; Surgery; X-ray imaging; C-arm positioning; Computer aided surgery; closed-form inverse kinematics; parallax-free X-ray image stitching; Algorithms; Biomechanics; Femur; Humans; Models, Theoretical; Phantoms, Imaging; Radiography, Interventional; Robotics; Spine; Surgery, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2012.2185708
  • Filename
    6140975