• DocumentCode
    1433740
  • Title

    Some direct measurements of edge capacitance

  • Author

    White, J. R Blanco

  • Author_Institution
    University of Cambridge, St. John´´s College, Cambridge, UK
  • Volume
    120
  • Issue
    8
  • fYear
    1973
  • fDate
    8/1/1973 12:00:00 AM
  • Firstpage
    939
  • Lastpage
    940
  • Abstract
    The edge capacitance of an electrode system was measured in a 3-terminal bridge network, and was therefore determined directly, rather than as a small difference. Kirchhoff´s formula was confirmed to within about 10%. The distribution of edge capacitance at various distances from the electrodes agreed with that predicted in a companion paper by Lynch (p. 934).
  • Keywords
    bridge instruments; capacitance measurement; electrodes; Kirchhoff´s formula; direct measurements; edge capacitance; electrode system; three terminal bridge network;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1973.0209
  • Filename
    5251699