Elimination of birefringence induced scale factor errors in the in-line Sagnac interferometer current sensor
Author :
Short, Shayne X. ; De Arruda, Josiel U. ; Tselikov, Alexandr A. ; Blake, James N.
Author_Institution :
Dept. of Electr. Eng., Texas A&M Univ., College Station, TX, USA
Volume :
16
Issue :
10
fYear :
1998
fDate :
10/1/1998 12:00:00 AM
Firstpage :
1844
Lastpage :
1850
Abstract :
This paper presents theoretical and experimental results showing the effects of linear and circular birefringence on the sensing coil of an in-line Sagnac interferometer current sensor. Linear birefringence induces local scale factor variations along the length of the sensing coil which can be suppressed with circular birefringence. We show that by winding the sensing coil with tension in a helix configuration, these variations may be effectively reduced to zero for ordinary single mode fiber. In our opinion, this method of implementation overcomes the need to use annealed fiber in the sensing coil
Keywords :
birefringence; electric current measurement; fibre optic sensors; light interferometers; measurement errors; sensitivity; birefringence induced scale factor errors; circular birefringence; fibre optic sensors; helix configuration; in-line Sagnac interferometer current sensor; local scale factor variations; ordinary single mode fiber; sensing coil; Annealing; Birefringence; Coils; Magnetic sensors; Optical fiber devices; Optical fiber polarization; Optical fiber sensors; Optical interferometry; Optical sensors; Sagnac interferometers;
fLanguage :
English
Journal_Title :
Lightwave Technology, Journal of
Publisher :
ieee
ISSN :
0733-8724
Type :
jour
DOI :
10.1109/50.721071
Filename :
721071
Link To Document :
بازگشت